Defibrillator S8
The S8 defibrillator monitor is used for manual defibrillation, automatic defibrillation in AED mode, external pacing and monitoring of physiological parameters of patients' vital signs (ECG, HR, RESP, SpO2, IR, BP, NIAT, TEMP, IAT).
Features:
Category: Defibrillators
NIAT measurement mode: Manual, AUTO, Continuous
Heart rate measurement range: 15-350 bpm
Respiratory rate measurement range (RESP): 0 - 150 breaths/min
Price: 246 000
Manager consultation
Order

The S8 defibrillator monitor is used for manual defibrillation, automatic defibrillation in AED mode, external pacing and monitoring of physiological parameters of patients’ vital signs (ECG, HR, RESP, SpO2, IR, BP, NIAT, TEMP, IAT).

Features:

  • The color display is 8.4 inches.
  • Manual defibrillation mode.
  • Automatic mode of an automated external defibrillator (AED).
  • Pacemaker mode.
  • Monitoring mode:
  • ECG-12/5/3 leads (heart rate, ST segment analysis, arrhythmia analysis);
  • Respiratory rate (RESP);
  • SpO2 (blood oxygen saturation);
  • IP (perfusion index);
  • HR (heart rate);
  • NIBP (systolic, mean, diastolic);
  • TEMP (on two channels);
  • Thermal printer.
NIAT measurement mode:
Manual, AUTO, Continuous
Heart rate measurement range:
15-350 bpm
Respiratory rate measurement range (RESP):
0 - 150 breaths/min
SpO2 measurement range:
0 ~ 100%;
Temp measurement range:
0~50°C, 2 channels
Measurement of NIAT parameters:
Systolic pressure, Diastolic pressure, Mean pressure
Display.:
8.4 - inch, color, maximum display of 4 oscillograms in monitoring mode, or 12 oscillograms in 12-lead ECG mode
Defibrillation mode:
Manual defibrillation (asynchronous mode), manual defibrillation (synchronized cardioversion), automatic external defibrillation (AED)
Defibrillation waveform:
Biphasic truncated exponential discharge pulse
Electrodes for defibrillation:
Reusable external defibrillation pads (adults and children), disposable external defibrillation pads (adults)
Choosing energy:
1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 15 / 20 / 30 / 50 / 70 / 100 / 120 / 150 / 170 / 200 / 220 / 250 / 270 / 300 / 360 J
Electrocardiostimulation (ECS):
Fixed ECS, ECS on demand, Stimulation frequency: 40 ~ 170 ppm Stimulation current: 0 ~ 200 mA
ECG monitoring (ECG):
ECG monitoring and measurement is available from 12/5/3-lead cable, reusable defibrillation pads, disposable defibrillation pads
Perfusion index (PI) measurement range:
0.05 - 20 %
Heart rate measurement range (HR):
20 - 254 beats/min (from SpO2 sensor), 40 - 240 beats/min (from NIBP sensor), 20 - 350 beats/min (from IAT sensor).
Measurement of IAT parameters (IBP):
2 channels; ART, PA, CVP, RAP, LAP, ICP, P1, P2, LV, Ao, UAP, BAP, FAP, UVP, IAP Static pressure measurement range: -50~+300 mmHg